- Página de inicio /
- suministros industriales /
- Lab & Scientific Products /
- Lab Instruments & Equipment /
- Electrochemistry Accessories /
- Silver Silver Chloride Reference Electrode. R...
Silver Silver Chloride Reference Electrode. R0303 Ag/AgCl Reference Electrode. Removable and Liquid Filled.(1 Pieces)
GTQ 551
Price Details
Excluding Shipping & Custom charges ( Shipping and custom charges will be calculated on checkout )
*All items will import from Estados Unidos
QTY:
Ubuy works hard to protect your security and privacy. Our advanced payment security system ensures confidentiality by encrypting your information during transmission using AES (Advanced Encryption Standards) and SSL (Secure Socket Layer) protocols. Your payment details are 100% secure as we do not share your payment details with third party sellers.
Restore functionality with ease: simply air and soak your electrode for optimal performance.
Fast
Shipping
Free
Return*
Secure Packaging
100% Original Products
PCI DSS Compliance
ISO 27001 Certified
Detalles de producto
- In the laboratory, if the resistance increases, it may be "the porous ceramic is dry. At this time, you can pull the glass tube out of the polytetrafluoroethylene cap, let a little air into the glass tube, and then place the glass vertically. After the bubble is driven out of the glass tube with the nail bullet, and then insert the glass into the PTFE sleeve. At this time, the KCl solution can extrude the porous ceramic through pressure, so as to restore the channel shape. At the same time,
- the electrode resistance can be reduced and the electrode can be used normally.
- When the electrode is not used, the electrode can be soaked in saturated potassium chloride
- solution, or on the protective cap, and stored dry. Before the second use, please immerse it in
- saturated potassium chloride solution for about 2 hours to activate the electrode.
| Package Dimensions | 1.18 x 0.79 x 0.39 inches (3 x 2 x 1 cm) |
| Item Weight | 1.76 ounces (49.9 grams) |
| Department | Unisex Adult |
| Manufacturer | sujeniir |
| Item model number | sujeniir23905 |
| Assembly required | No |
| Number of pieces | 1 |
DESCRIPCIÓN DEL PRODUCTO
Preguntas y respuestas de los clientes
-
Pregunta:
What is a Silver Silver Chloride Reference Electrode?
Respuesta: A Silver Silver Chloride Reference Electrode is a crucial device used in electrochemistry for maintaining a stable reference potential. This electrode typically consists of a silver wire coated with silver chloride, immersed in a liquid electrolyte. It provides consistent and reliable measurements in various chemical analysis applications, including pH measurement and voltammetry, where accurate potentials are a must for reliable experimental results. -
Pregunta:
How do I use the R0303 AgAgCl Reference Electrode?
Respuesta: To use the R0303 AgAgCl Reference Electrode, first ensure that it is properly filled with the appropriate electrolyte solution. Connect the electrode to your measurement device, ensuring proper polarity. Immerse the electrode in the solution where measurements are to be taken. The removable design allows for easy maintenance and precise calibration, making it ideal for various lab experiments and research applications, especially in potentiometric measurements. -
Pregunta:
What are the advantages of a removable and liquid-filled design?
Respuesta: The removable and liquid-filled design of the Silver Silver Chloride Reference Electrode offers several advantages. It allows for easy replacement of the electrolyte solution, ensuring optimal performance and accuracy during experiments. Additionally, the liquid-filled feature enhances stability and response time. This design is particularly beneficial in laboratory settings where rapid data collection is crucial, as it can be easily adapted to different solutions without the need for a complete electrode replacement. -
Pregunta:
In which applications is the Silver Chloride Reference Electrode commonly used?
Respuesta: The Silver Chloride Reference Electrode is commonly used in various electrochemical applications, including pH measurement, potentiometric titrations, and corrosion studies. Its stable reference potential makes it perfect for laboratory setups and field measurements in environmental monitoring. Researchers often rely on this type of electrode due to its reliability and accuracy, which are essential when analyzing chemical reactions and understanding reaction kinetics. -
Pregunta:
What is the lifespan of a Silver Silver Chloride Reference Electrode?
Respuesta: The lifespan of a Silver Silver Chloride Reference Electrode depends on usage conditions and maintenance practices. Properly maintained, these electrodes can last for extended periods, especially if used in low-contamination environments. Regular checking of the electrolyte levels and timely replacement help ensure optimal performance. In situations where frequent recalibration is required, you might find yourself needing to replace the electrode more often if it has been exposed to harsh chemicals or conditions. -
Pregunta:
How should I store my Silver Chloride Reference Electrode?
Respuesta: To ensure optimal performance, store your Silver Chloride Reference Electrode in a suitable storage solution, typically the same electrolyte used during operation. It is critical to avoid letting the electrode dry out, as this can lead to an inaccurate reference potential. For long-term storage, seal it in a container that minimizes exposure to air and contaminants. Doing so ensures that the electrode maintains its functionality for future experiments. -
Pregunta:
Can I use this electrode with any type of pH meter?
Respuesta: Yes, the Silver Silver Chloride Reference Electrode is compatible with a wide range of pH meters. It is essential, however, to ensure that your pH meter can accommodate a reference electrode connection. Compatible meters typically have a BNC or similar connector for easy integration. Using this highly stable electrode will enhance measurement accuracy and reliability, making it a preferred choice for laboratory specialists and quality control analysts. -
Pregunta:
What should I do if my electrode shows erratic readings?
Respuesta: If your Silver Chloride Reference Electrode shows erratic readings, begin by checking the electrolyte level to ensure it is filled correctly. Contamination or depletion of the electrolyte can lead to unstable readings. Consider recalibrating your measuring device and inspecting the connections for any loose wires. If problems persist, inspect the electrode for signs of damage or wear, and consider replacing it to regain measurement reliability. -
Pregunta:
Where can I buy a Silver Silver Chloride Reference Electrode?
Respuesta: You can purchase the Silver Silver Chloride Reference Electrode from Ubuy in Guatemala. Ubuy offers a reliable selection of electrochemical equipment, including various models of reference electrodes, ensuring you find the right product for your lab needs.
sujeniir Electrochemistry Accessories sujeniir23905 Editorial Review
Customer Reviews & Ratings
-
5 estrella
100%
-
4 estrella
0%
-
3 estrella
0%
-
2 estrella
0%
-
1 estrella
0%
Revisar este producto
Comparte tus ideas con otros clientes
Platform Trust & Buyer Confidence
“The product received very good packaging & safe…Thank You”
“Accurate delivery timing given”
“Not madly expensive like I thought, and much quicker than promised.”
“Never dealt with Ubuy before, but everything worked out great. Seamless cross border purchasing and shipping. Thanks!”
“The process was smooth, with clear communication and timelines. This was my 1st purchase and I am really impressed. I will definitely be coming back.”
Product Price History
Información importante
- Limitaciones: Para los productos enviados al extranjero, ten en cuenta que cualquier garantía del fabricante puede no ser válida; las opciones de servicio del fabricante pueden no estar disponibles; los manuales del producto, las instrucciones y las advertencias de seguridad pueden no estar en los idiomas del país de destino; los productos (y los materiales que los acompañan) pueden no estar diseñados de acuerdo con las normas, especificaciones y requisitos de etiquetado del país de destino; y los productos pueden no ajustarse al voltaje del país de destino y a otras normas eléctricas (lo que requiere el uso de un adaptador o convertidor, si procede). El destinatario es responsable de asegurarse de que el producto puede ser importado legalmente al país de destino. Cuando hagas un pedido a Ubuy o a sus filiales, el destinatario es el importador registrado y debe cumplir todas las leyes y normativas del país de destino.
- No todos los productos que aparecen en Ubuy están a la venta, ya que Ubuy es un motor de búsqueda a nivel mundial. Los productos están sujetos a las normas de exportación/comercio.
GTQ 551
Haz tu pedido ahora y recíbelo por ahí Viernes, Agosto 21
This item is not restrict in my country.(Please click on above link if this item is not restrict in your country, So our team will review and allow.)
QTY:
PCI DSS compliant and ISO 27001:2022 certified, with encrypted payments and full buyer protection on every order.
características y beneficios
- Removable and liquid-filled for easy maintenance.
- Quickly restore functionality by rehydrating the porous ceramic.
- Store in saturated potassium chloride solution for longevity.
- Ideal for laboratory use with reliable performance.
- User-friendly design for fast activation and preparation.
- Enhances accuracy by reducing electrode resistance.
Ubuy Assurance
Experience worry-free shopping with 100% original products, PCI DSS-compliant payment security, ISO 27001-certified data protection, the fastest cross-border delivery, free returns *, and secure packaging on every order.


